<LOGO>
FM Transmitter Measurement Report
Created: 2024-06-26 13-24-16
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
93.40 MHz 5/5, 38 dBuV VIBRA fm
Pilot RDS Phase Difference
6.6 kHz 3.3 kHz -87 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
15 kHz 66 kHz 7152 0,1957
Modulation Power
Limit Measuring Tolerance
11,0 dBr 0,2 dBr
MIN AVE MAX % above 11,2 dBr
5,3 dBr 6,86 dBr 7,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VIBRA fm" F560 9 (Varied) 1 0 1 1 --:--
RT
"TAYLOR SWIFT Ft POST MAL "
AF EON
90.3, 93.4, 101.7, 102.0, 102.1 MHz -
FM Scope Station: 93.40 MHz, signal: 5/5 (38 dBuV) Max at: 66 kHz MIN: 15 kHz % above 75 kHz: 0,1957 Acquired: 2024/06/26 13:23:12 Total samples: 7152 Equivalent time: 0:05:57 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600